Inverter

Inverter

Thanks to a "made to measure" and with great design flexibility, the Inverter can be made to satisfy any plant requirement. It can be operated with D.C. input voltage from 24Vdc up to 600Vdc, with single phase or three phase output voltage according to the load topology, the output power and adapted to the D.C. voltage available in the Plant. All of them are provided with output isolation transformer which increase the robustness permitting to operate in application having the earth completely isolated (IT systems) It can be provided with emergency line static switch, manual by-pass and/or voltage stabilizer.

Customization

Our A.C. systems can be extremely customized, even mechanically. The cabinets can be made on request with specific dimension, colour, door opening and protection degree IP. Big systems can be divided in more sections for an easier transportation & installation. The internal components, material & circuit breakers may be chosen respecting a Customer's vendor list and much more.

GENERAL TECHNICAL CHARACTERISTICS

Input: Single phase 110-230Vac 50÷60Hz
Three phase 200-400-415 Vac 50÷60 Hz
Battery Charger: intended for battery recharging according to the relevant specifications, either lead, or sealed lead, or nickel-cadmium battery, it can be provided with fully- controlled (6 pulse) or dodeca-phase (12 pulse) rectifier bridge. An A.C. input isolation transformer can also be included
Inverter: it is made with PWM technology using IGBT power modules and provided of output isolation transformer. The electronic control card is microprocessor based
Static Switch: it is made with high power Thyristor (SCR) with very fast switching between inverter-mains, and vice versa, in zero time. The electronic control card is microprocessor based
Manual By-Pass: always available with static switch, it is very useful for a complete output side sectioning for maintenance. Made with the “Make-Before-Break” configuration, it ensures manoeuvres without any micro-interruption of the power the load
Emergency Line Stabilizer: Under request, an emergency line voltage stabilizer can be added. In this case, the output voltage will be stabilized within ±2% even with inverter OFF
Parallel & Redundant: both UPS & Inverters may be made according to redundant configuration or with more paralleled systems
Distribution: the systems can be provided with integral, or separated, load distribution avoiding a further external distribution panel

CONTACT US

for information or quotations